Regional performance targets for transparent near-infrared switching electrochromic window glazings

TitleRegional performance targets for transparent near-infrared switching electrochromic window glazings
Publication TypeJournal Article
Year of Publication2013
AuthorsNicholas DeForest, Arman Shehabi, Guillermo Garcia, Jeffery B Greenblatt, Eric R Masanet, Eleanor S Lee, Stephen E Selkowitz, Delia J Milliron
JournalBuilding and Environment
Volume61
Pagination160 - 168
Date Published03/2013
ISSN03601323
KeywordsDynamic windows, Electrochromic glazings, NIR-switching, Performance targets, Solar heat gain
Abstract

With building heating and cooling accounting for nearly 14% of the national energy consumption, emerging technologies that improve building envelope performance have significant potential to reduce building energy consumption. Actual savings from these technologies will depend heavily upon their performance in diverse climate and operational conditions. In many cases, early-stage research can benefit from detailed investigation in order to develop performance thresholds and identify target markets. One example, a dynamic, highly transparent, near-infrared switching electrochromic (NEC) window glazing, is the focus of this investigation. Like conventional electrochromics, the NEC glazing can dynamically tune its optical properties with a small applied voltage. Consequently, the glazing can block or transmit solar heat to reduce cooling or heating loads, respectively. Unlike conventional electrochromics, NEC glazings remain transparent to visible light, causing no adverse effect to daylighting or building aesthetics. This study utilizes the software COMFEN to simulate a broad range of NEC performance levels, for commercial and residential buildings in 16 climate-representative reference cities. These simulations are the basis for identifying performance levels necessary to compete with existing static technologies. These results indicate that energy savings are strongly influenced by blocking-state performance. Additionally, residential applications have lower performance requirements due to their characteristic internal heat gains. Finally, the most dynamic NEC performance level is simulated in competition with high performing static alternatives. Here heating and cooling energy savings range from 5 to 11 kWh/m2 yr for commercial and 8–15 kWh/m2 yr for residential, in many regions on the order of 10%.

DOI10.1016/j.buildenv.2012.12.004
Short TitleBuilding and Environment